Clarity Wind Module Siting Guide

Wind measurements are only as good as the Module's exposure to open air, so siting matters a lot here. This guide covers the key considerations. If you'd like help, email support@clarity.io. For general device siting, also see the Node-S siting guide.


Survey the site first

If you can, survey the site before deployment day. It helps you identify exactly where to mount the device, confirm site access and permissions, confirm power requirements, gather the right tools and mounting accessories (see deploying your Wind Module), and take photos or diagrams for later.


Choosing a mounting location

The Wind Module is typically mounted above the Node, on a deployment pole with a maximum outer diameter of 40 mm. For poles wider than 40 mm, you may need additional mounting materials to ensure adequate airflow around the Module.

A good mounting location should:

  • Be in an open area, clear of obstructions for at least 15 m in all directions.
  • Be at least 6 meters (20 ft) from obvious pollution sources like an exhaust vent, generator, or outdoor grill.
  • Avoid trees and tall buildings — ideally the Wind Module is the tallest object in the area, mounted 2 m or higher.
  • Be unobstructed for good airflow — ideally more than 270° of free airflow around the Module, and no less than 180°.
  • Avoid high-power radar or radio transmitters, to limit interference.
  • Be in a secure location, ideally behind a fence or away from heavy foot traffic.